18-22
Measure Commands
JITTer:FREQuency:MAXNumber
Returned Format [:MEASure:JITTer:FREQuency:COMPonents] <string><NL>
The following is an example of a returned string:
930 fs,78.37 MHz,rate/127,420 fs,622.1 MHz,rate/16,210 fs,1.244 GHz,rate/8, 121 fs, 56.43 MHz,----”
Example 10 OUTPUT 707;”:MEASURE:JITTER:FREQUENCY:COMPONENTS?”
JITTer:FREQuency:MAXNumber
Command :MEASure:JITTer:FREQuency:MAXNumber <max_async_freqs>
Sets the maximum number of asynchronous frequency components that the instrument will
detect. Detected components are analyzed in order of descending magnitude until the num-
ber of components specified with this command is obtained.
Restrictions Jitter mode. Software revision A.04.10 and above (86100C instruments). Option 200,
Enhanced Jitter Analysis Software.
Query :MEASure:JITTer:FREQuency:MAXNumber?
This query returns the maximum number of components setting.
Returned Format [:MEASure:JITTer:FREQuency:MAXNumber] <max_async_freqs><NL>
Example 10 OUTPUT 707;”:MEASURE:JITTER:FREQUENCY:MAXNUMBER 10”
JITTer:FREQuency:SCAN
Command :MEASure:JITTer:FREQuency:SCAN
Initiates a scan that calculates the absolute frequency of any significant asynchronous fre-
quency components up to the maximum number of components specified with the MEA-
Sure:JITTer:FREQuency:MAXNumber command. If the instrument is not in Jitter Mode (with
Option 200 installed), a “Settings Conflict” error is generated by this command.
Restrictions Jitter mode. Software revision A.04.10 and above (86100C instruments). Option 200,
Enhanced Jitter Analysis Software.
Example 10 OUTPUT 707;”:MEASURE:JITTER:FREQUENCY:SCAN”
JITTer:ISI?
Query :MEASure:JITTer:ISI?
Returns the inter-symbol interference value measured on the current source.
Restrictions Jitter mode. Software revision A.04.00 and above (86100C instruments).
Returned Format [:MEASure:JITTer:ISI] <value><NL>
Example 10 OUTPUT 707;”:SYSTEM:HEADER OFF”
20 OUTPUT 707;”:MEASure:JITTer:ISI?”
JITTer:LEVel?
Query :MEASure:JITTer:LEVel?
Returns the amplitude level at which jitter measurements are made.
Restrictions Jitter mode. Software revision A.04.00 and above (86100C instruments).
Returned Format [:MEASure:JITTer:LEVel] <value><NL>