Reelmaster 2300–D/2600–D
Page 5 – 30
Electrical System
Cutting Unit Solenoid Valve Coil
The solenoid valve coil can be easily replaced without
opening the hydraulic system.
Removal
1. Disconnect the electrical connector.
2. Remove the nut from the spool assembly.
3. Slide the coil assembly and O–rings from the spool
assembly. Discard the coil assembly and O–rings.
4. Clean any corrosion or dirt from the spool assembly.
Installation
1. Coat new O–rings lightly with petroleum jelly. Slide
new O–rings and new coil assembly onto the spool as-
sembly. Align the coil assembly evenly with the manifold
body.
2. Apply Loctite 242 or equivalent to the threads.
Screw the nut onto the spool assembly and torque to 15
in–lb (17 KG–CM). Do not over tighten.
3. Connect the electrical connector.
Figure 26
3
4
1
2
3
1. Nut
2. Coil assembly
3. O–ring
4. Spool assembly
Loctite 242