Reelmaster 2300–D/2600–D
Page 5 – 25
Electrical System
Seat Interlock Switch
This switch is a normally open switch that closes when
the operator is on the seat. If the cutting unit switch or
traction interlock switch is open and the operator raises
out of the seat, the engine will stop. The switch and its
electrical connector are located under the skirt below
the seat.
1. Disconnect switch electrical connector.
2. Check the continuity of the switch by connecting a
multimeter (ohms setting) across the connector termi-
nals.
Note: Make sure the compression spring and pin hold
the seat off the switch when there is no operator in the
seat.
3. With the seat lowered and no operator in the seat,
there should be no continuity between the terminals.
4. Have an operator slowly sit in the seat. There should
be continuity as the seat approaches the bottom of its
travel.
5. Connect switch electrical connector.
Figure 21
1
1. Seat interlock switch
Figure 22
1
1. Seat interlock switch
Electrical