Toro 3100-D Lawn Mower User Manual


 
Reelmaster 3100−D
Page 2 − 9
Product Records and Maintenance
Cutting Units
Each cutting unit has (6) grease fittings (with optional
front roller installed) that must be lubricated regularly
with No. 2 General Purpose Lithium Base Grease.
The grease fitting locations and quantities areas follows:
Bedknife adjuster (2), every 50 hours (Fig. 17); Reel
bearings (2) and front and rear rollers (2 ea.) (Fig. 16).
Note: Lubricate only one reel bearing grease fitting on
each end of cutting unit.
IMPORTANT: Lubricating cutting units immediately
after washing. This helps to purge water out of bear-
ings and increases bearing life.
1. Wipe each grease fitting with a clean rag.
IMPORTANT: Do not apply too much pressure or
grease seals will be permanently damaged.
2. Apply grease until pressure is felt against handle.
3. Wipe excess grease away.
Figure 17
Grease every 50 operating hours.
Figure 18
Grease every 8 operating hours.
Product Records
and Maintenance