Toro 5210/5410/5510/5610 Lawn Mower User Manual


 
Reelmaster 5010 Series Hydraulic System (Rev. C)Page 4 -- 115
Inspection
1. Backflushoilcoolerwithcleaningsolvent.Aftercool-
er is clean, make sure all solvent is drained from the
cooler.
CAUTION
Use eye protection such as goggles when using
compressed air.
2. Dry inside of oil cooler using compressed air in the
opposite direction of the oil flow.
3. Plug both ends of oil cooler. Clean exterior of cooler.
Make sure oil cooler fins are clear of dirt and debris.
4. The oil cooler should be free of corrosion, cracked
tubes and excessive pitting of tubes.
Installation (Fig. 97)
1. If removed, install hydraulic fittings, clamps and
bracketsto oilcooler usingFigures97 and98as guides.
On Reelmaster 5210 machines (not shown), apply hy-
draulic threadsealant onhydraulic fittingthreads before
installation.
2. Position oil cooler to radiator and secure with
clamps.
3. Install hydraulic hoses to oil cooler fittings and se-
cure with hose clamps.
4. Install radiator screen to machine. Close hood.
5. Check oillevel in hydraulic reservoirand add correct
oil if necessary.
1. Oil cooler
2. O--ring
3. Hyd fitting (2 used)
4. O--ring
5. Hyd fitting (2 used)
6. Hose clamp
7. Hyd hose (2 used)
8. Flat washer
9. Flange nut (4 used)
10. Clamp (2 used)
11. Cap screw (2 used)
12. Screw (8 used)
13. Oil cooler bracket
14. Mount plate (2 used)
Figure 98
4
3
1
2
9
10
11
8
5
6
7
12
8
13
14
12
REELMASTER 5610
FRONT
RIGHT
Hydraulic
System