Greensmaster eFlex 1800/2100 Page 4 -- 35 Electrical System
Reel Engage Switch Testing
1. Park machine on level surface and place traction le-
ver in the NEUTRAL position. Turn key switch to the
OFF position and remove key from the switch. Discon-
nect the battery pack (see Lithium Battery Pack Con-
nection in the General Information section of this
chapter).
2. Remove console cover from handle to allow access
to reel engage switch (Fig. 42). Disconnect reel engage
switch connector from the machine wire harness.
3. Check the continuity of the reel engage switch by
connecting a multimeter (ohms setting) across the
switch connector terminals.
4. With the cutting reel drive not engaged, there should
not be continuity (infinite ohms) across the switch termi-
nals.
5. Verify that the switch closes (zero ohms) as the cut-
ting reel drive is engaged.
6. Replace switch if necessary.
Reel Engage Switch Removal/Installation
1. Disconnect reel engage switch from the machine
wire harness.
2. Remove screws and lock nuts that mount switch to
switch panel on handle (Fig. 42). Remove switch from
machine.
NOTE: For proper r eel engage switch operation, the
screws and lock nuts used to secure the reel engage
switch are stainless steel. If these fasteners are re-
placed, make sure to use correct fasteners.
3. Position switch to switch panel and secure with
screws and lock nuts (Fig. 42).
4. Connect the battery pack (see Lithium Battery Pack
Connection in the General Information section of this
chapter).
1. Engagement lever
2. Reel engage switch
3. Reel lever tab
Figure 43
1
3
2
Electrical
System