Toro 4043 Greenhouse Kit User Manual


 
Greensmaster eFlex 1800/2100 GroomerPage 7 -- 9
Installation
1. If removed, install shaft into groomer cover (Fig. 6):
A. InstallnewO--ringintogrooveofshaft.
B. Apply antiseize lubricant to shaft surface that is
below the retaining ring groove.
C. Slide shaft up through bore of cover and secure
with thrust washer and retaining ring. Position shaft
in cover so that cam point of shaft is located away
from the gasket surface (Fig. 7).
D. Install plunger detent into groomer cover so that
end of plunger if from flush to 0.020” (0.5 mm) ex-
tending from cover surface (Fig. 7).
E. Slide handle into shaft so that it extends toward
the front of the cover.
F. Apply Loctite #242 (or equivalent) to threads of
set screw. Install set screw into end of shaft tosecure
handle in place.
2. Install groomer cover assembly to RH drive plate as-
sembly (Fig. 5):
A. Make sure that handle on groomer cover is ro-
tated toward t he front of the machine.
B. Fill groomer cover with approximately five (5)
ounces (142 grams) of Mobil XHP221 grease (or
equivalent).
C. Install new gasket and then groomer cover as-
sembly to RH drive plate. Secure cover with five (5)
flange head screws.
3. Connectthe battery pack(see Battery Pack Connec-
tion in the General Information section of this chapter).
1. Shaft
2. Cam point
3. Plunger detent
Figure 7
2
1
3
Flush to 0.020”
(Flush to 0.5 mm)
Groomer