Greensmaster eFlex 1800/2100 Page 4 -- 17 Electrical System
Operator Advisories
Operator advisories a re automatically displayed by the
InfoCenter when a machine function requires additional
action (Fig. 18). An advisory will not be logged into the
fault log.
InfoCenter advisories include the following:
System Shutdown (#201): This advisory notifies the
operator that the machine is shutting down. Because the
shutdown process takes some time, this advisory is dis-
played so that an operator is aware of the shutdown and
machine operation is not available. The shutdown advi-
sory will be displayed after the key switch is turned OFF.
Low Battery Shutdown (#202): If the battery state of
charge is too low for continued machine operation, the
low battery shutdown advisory will notify the operator
that the machine will automatically shutdown. Battery
charging is necessary before returning the machine to
normal operation.
Energy Saving Mode Active(#203): If thebattery state
of charge is too low for normal m achine operation, the
energy saving mode active advisory will notify the oper-
ator that themachine is operating with reducedfunction-
ality (cutting unit disengaged and reduced traction
speed). Battery charging is necessary before returning
the machine to normal operation.
Energy Saving Mode Warning (#204): If the battery
state of charge is too low for normal machine operation,
the energy saving mode warning advisory will notify the
operator that the machine will start operating with re-
duced functionality (cutting unit disengaged and re-
duced traction speed) in approximately 30 seconds.
Battery charging is necessary before returning the ma-
chine to normal operation.
BatteryCurrent Limit (#205): This advisory notifies the
operator that the electric motor drive current has been
lowered by the lithium battery pack controller. T he oper-
ator may notice lower machine performance. For exam-
ple, the Battery Current Limit advisory would be
displayed if the battery pack temperature is excessive.
Use Handbrake (#206): This advisory notifies the oper-
ator that the electric motor regenerative braking current
has been lowered by the lithium battery pack controller
which will affect the motor braking system. In this
instance, the operator may have t o use the handbrake
to slow the machine. The Use Handbrake advisory
would be displayed, for example, if themowerwitha fully
charged battery was going down a long hill during op-
eration.
Motor Current Limit (#207): This advisory notifies the
operator that the electric motor is already running at
maximum current and cannot deliver any additional per-
formance. For example, the motor current limit advisory
would be displayed if the speed control was increased
when the motor was already providing maximum perfor-
mance.
Brake On (#209): The brake on advisory will notify the
operator that the parking brake latch is engaged when
attempting to engage the traction drive system.
High Power Consumption Run Time Reduced
(#210): The high power consumption identifies that
electric motor draw is excessive and will reduce the run
time of the machine. Excessive cutting unit bedknife
contact or accessory use may generate this advisory.
Motor Disabled (#212): The motor disabled advisory
will identify that electric motor operation was stopped by
the controller. A fault should have been generated that
will provide additional information as to cause of the is-
sue.
Disengage Traction (#213): This advisory notifies the
operator that the traction lever is engaged and needs to
be released before operation can be continued. Thedis-
engage traction advisory will be displayed if themachine
is turned on with the t raction lever already engaged.
1. Advisory identification 2. Advisory name
Figure 18
1
2
Advisory #209
Brake On
Electrical
System