Removal and Installation Procedures
AWG510 & AWG520 Service Manual
6-21
6. Remove the EMI gaskets:
a. Look for the point where the ends of the gasket touch in the channel at
the rear edge of the cabinet.
b. Use a pair of needle-nose pliers to pry up one of the ends.
c. Grasp the EMI gasket, and gently pull it out of the its channel.
d. Repeat substeps a through c to remove the gasket from its channel on the
front casting.
7. Reinstallation of EMI gaskets: Press each EMI gasket back into its groove at
the rear edge of the cabinet or front casting. Make sure the ends of the gasket
touch, but do not overlap, when installing. (Cut off excess length if required
to prevent overlap.)
8. Reinstallation of cabinet and rear cover:
a. Do in reverse order steps 3 and 4 to reinstall the cabinet.
b. Take care not to bind or snag the cabinet on internal cabling; redress
cables an necessary.
c. When sliding the cabinet, be sure that the front edge of the cabinet aligns
with the groove containing the EMI shield on the front casting.
d. Be sure that the ridge around the rear chassis slides into the groove
containing a second EMI cable on the rear of the cabinet.
e. When reinstalling the four screws at the rear panel, tighten them to
16 foot-lbs torque.
f. See the procedure Line Fuse and Line Cord to reinstall the line cord,
which completes the generator reassembly.