Control Panel Options 107
E-EQ-MX3RFIDRG-A MX3-RFID Reference Guide
Strip Code ID
Enabling this parameter removes the number of characters (specified by AIM Code ID or Symbol
Code ID radio button setting) before the barcode is sent to the application.
Figure 3-23 Barcode – Advanced Processing – Strip Code ID
This checkbox is unavailable when Data includes no Code ID radio button is enabled.
Strip Identifiers from EAN128 Barcodes
When Strip Code ID is disabled (unchecked), the AIM Code or Symbol Code ID is included in the
barcode data being matched.
Scanned barcodes are not matched against the following parameters unless they are EAN128
barcodes. If the scan engine does not support EAN128 barcodes, or EAN128 barcodes have been
disabled, the Strip Identifiers from EAN128 Barcodes function is not available.
Figure 3-24 Barcode – Advanced Processing – EAN128 Barcodes
The user specifies whether the barcodes have an AIM Code ID (3 characters) or a Symbol Code
ID (1 character). They also specify whether the AIM or Symbol Code ID will be stripped or
passed through to the Codes match, as long as the barcode is an EAN128 barcode.