Control Panel Options 97
E-EQ-MX3RFIDRG-A MX3-RFID Reference Guide
COM1, COM2, COM3 Tabs
Do not connect a tethered scanner to the USB labelled ports:
COM Default Options
COM1 MX3-RFID (pre-set and dimmed) –
115200, 8 data bits, 1 stop bit, no parity,
Power on pin 9 enabled
Baud Rate – 115200 (RFID only), 38400,
19200, 9600, 4800, 2400, 1200
Data Bits – 8, 7
Stop Bits – 1, 2
Parity – None, Odd, Even, Mark, Space
COM2 9600, 8 data bits, 1 stop bit, no parity
Power on pin 9 (+5v) Disabled
Baud Rate – 38400, 19200, 9600, 4800,
2400, 1200
Data Bits – 8, 7
Stop Bits – 1, 2
Parity – None, Odd, Even, Mark, Space
COM3 9600, 8 data bits, 1 stop bit, no parity
Power on pin 9 (+5v) Disabled
Baud Rate – 38400, 19200, 9600, 4800,
2400, 1200
Data Bits – 8, 7
Stop Bits – 1, 2
Parity – None, Odd, Even, Mark, Space
Adjust the settings and tap the OK box to save the changes. The changes take effect immediately.