CHAPTER 4—USING THE REMOTE MANAGEMENT UTILITY
LIBRARY STATUS
The Library Status section includes the following information:
Field Indicates...
LCD the current message displayed on the autoloader’s LCD
Motion the type of motion currently being performed by the
cartridge loader
Robot Control
Mode
the current operating mode for the autoloader (Random or
Sequential)
See page 38 for information about operating modes. You
can change the robot control mode from the utility’s
Configuration page (see page 53).
Door
Open/Closed
Sensor
the current reading of the door sensor for the cartridge
access port door: Door Open or Door Closed
Library
Temperature
whether the autoloader’s current internal temperature is
within the normal operating range. See page 123 for
operating temperature requirements.
Front Door
Locked or Not
Locked by Host
whether or not the cartridge access port is locked by an
application. (For security purposes, an application can issue
a PREVENT MEDIUM REMOVAL command to the
autoloader to disable the cartridge access port.)
Language the current language used on the autoloader’s LCD
You can change the LCD language from the utility’s
Configuration page (see page 53).
Auto Clean
ON/OFF
whether the autoloader is set to perform clean the tape
drive automatically when required
See page 32 for information about the Autoclean option.
You can change the Autoclean option from the utility’s
Configuration page (see page 53).
Cleaning Tape
Installed/No
Cleaning Tape
Installed
whether cell 7 in the autoloader has been designated as the
storage location for a cleaning cartridge
See page 32 for information about enabling the cleaning
cartridge cell. You can enable the cleaning cartridge cell
from the utility’s Configuration page (see page 53).