506
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
FVC O Mes Message Fields
Figure 54 FVC O Mes Message Fields
T1T2
This field identifies the received message as an order confirmation, an order, or a called
address message.
2 binary characters required.
SCC
SAT color code for new channel.
2 binary characters required.
PSCC
Present SAT color code. Indicates the SAT color code associated with the present channel.
2 binary characters required.
RSVD
Reserved for future use, all bits must be set as indicated.
9 binary character required.
LOCAL
Local control field. This field is specific to each system. The ORDER field must be set to
local control for this field to be interpreted.
5 binary character required.