Agilent Technologies A.18.00 Weather Radio User Manual


 
484
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
Chapter 8, Programming the Call Processing Subsystem
Programming the CALL BIT Screen
Reading the CALL BIT Screen Message Fields
This section provides programming information on how to read the contents of
individual fields in the signaling messages available on the
CALL BIT screen.
The syntactical structure for reading the contents of one or more fields from an
individual message is as follows:
General Syntax
CALLP:<message name>:<field name><?>[<;><additional field><?>]
Table 50 on page 484 lists the message names used to access each of the signaling
messages available on the
CALL BIT screen.
Example of Querying A Single Field
OUTPUT 714;"CALLP:MESS ’SPC WORD1’"
OUTPUT 714;"CALLP:SPOM1:SID?"
ENTER 714;Sid$
PRINT Sid$
Example Printout
"00000001110011"
Table 50 CALL BIT Screen Signaling Message Names
Message Message Name
SPC WORD1 SPOM1/SPOMESSAGE1
SPC WORD2 SPOM2/SPOMESSAGE2
ACCESS ACCess
REG INC RINCrement
REG ID RIDentify
C-FILMESS CFMessage
MS WORD1 MSWord
MSMessOrd MSORder
MS IntvcH MSVoice
FVC O Mes FVORder
FVC C Mes FVVoice