490
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
E
This field displays the extended address word sent to the mobile.
• Set to ‘1’ if the extended address word is sent.
• Set to ‘0’ if the extended address word is not sent.
1 binary character required.
REGH
Registration field for home stations.
1 binary character required.
REGR
Registration field for roaming stations.
1 binary character required.
DTX
Discontinuous transmission field.
2 binary characters required.
N-1
N is the number of paging channels in the system.
5 binary characters required.
RCF
Read-control-filler field.
1 binary character required.