496
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
REG ID Message Fields
Figure 49 REG ID Message Fields
T1T2
This field identifies the received message as an order confirmation, an order, or a called
address message.
2 binary characters required.
DCC
Digital color code field.
2 binary characters required.
REGID
Registration ID field.
20 binary character required.
END
End indication field.
• Set to 1 to indicate the last word of the overhead message train.
• Set to 0 if not the last word.
1 binary character required.