Toro 4700-D Lawn Mower User Manual


 
Groundsmaster 4500--D/4700--DPage 5 -- 34Electrical System
Battery Service
The battery is the heart of the electrical system. With
regularand properservice, batterylifecan beextended.
Additionally, battery and electrical component failure
can be prevented.
CAUTION
When working with batteries, use extreme cau-
tion to avoid splashing or spilling electrolyte.
Electrolyte candestroy clothingand burnskin or
eyes. Always wear safety goggles and a face
shield when working with batteries.
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80
o
F (26.7
o
C)
Discharged: less than 1.240
Battery Specifications
BCI Group Size 24
650 CCA at 0
o
F (--17.8
o
C)
Reserve Capacity of 105 minutes at 80
o
F (26.7
o
C)
Dimensions (including terminal posts and caps)
Length 11 inches (27.9 cm)
Width 6.76 inches (17.2 cm)
Height 9.2 inches (23.4 cm)
Battery Removal and Installation (Fig. 48)
1. Unlatch and raise operator’s console panel behind
the operator seat to access battery.
2. Loosen and remove negative cable from battery. Af-
ter negative cable is removed, loosenand remove posi-
tive cable from battery.
3. Loosen strap that secures battery to machine.
4. Carefully remove battery from machine.
5. Install battery in reverse order making sure to con-
nect and tighten positive cable to battery before con-
necting the negative cable.
NOTE: Beforeconnecting the negative (ground) cable,
connect a digital multimeter (set to amps) between the
negative battery post and the negative (ground) cable
connector. The reading should be less than 0.1 amp. If
the reading is 0.1 amp or more, the machine’s electrical
system should be tested for short circuits or faulty com-
ponents and repaired.
6. Make sure that rubber boot is properly placed over
positive cable end and positive battery post.
7. Lower and secure operator’s console panel.
1. Negative cable
2. Positive cable
3. Battery strap
Figure 48
2
1
3
Battery Inspection and Maintenance
1. Replace battery if case is cracked or leaking.
2. Check battery terminal posts for corrosion. Use wire
brush to clean corrosion from posts.
IMPORTANT: Before cleaning the battery, tape or
block vent holesto the filler capsand make surethe
caps are on tightly.
3. Check for signs of wetness or leakage on the top of
the battery which might indicate a loose or missing filler
cap, overcharging, loose terminal post or overfilling.
Also, check battery case for dirt and oil. Clean the bat-
tery with a solution of baking soda and water, then rinse
it with clean water.
4. Check that the cover seal is not broken away. Re-
place the battery if the seal is broken or leaking.
5. Check the electrolyte level in each cell. If the level is
below the tops of the plates in any cell, fill all cells with
distilled water between the minimum and maximumfill
lines. Charge at 15 to 25 amps for fifteen (15) minutes
to allow sufficient mixing of the electrolyte.