Toro 4700-D Lawn Mower User Manual


 
Groundsmaster 4500--D/4700--D Hydraulic SystemPage 4 -- 111
5. Removefour(4)capscrewsandwashersusedtose-
cure fan (item 13) to fan hub. Remove fan.
IMPORTANT: Make sure to not damage the radiator
or other machine components while loosening and
removing the fan motor and bracket assembly.
6. Remove cooling fan motor and bracket assembly.
A. To prevent contamination of hydraulic system,
thoroughly clean exterior of fan motor and fittings.
B. Disconnect hydraulic hoses from fan motor. Put
caps or plugs on fittings and hoses to prevent con-
tamination. Label hydraulic lines for proper assemb-
ly.
C. Remove six ( 6) cap screws and flange nuts that
secure fan motor bracket to radiator.
D. Carefully remove fan motor and bracket assem-
bly from machine and place on suitable work sur-
face.
7. Removehexnut (item9)and washer(item8) thatse-
curefan hubto fanmotor.Use suitablepuller tocarefully
remove fan hub from fan motor shaft. Locate and re-
trieve woodruff key.
8. Remove two (2) cap screws (item 20), flat washers
(item 21) and lock nuts (item 14) that secure fan motor
to fan motor bracket. Remove fan motor from bracket.
9. Ifhydraulic fittings areto beremoved fromfan motor,
mark fitting orientation to allow correct assembly. Re-
move fittings from motor and discard O--rings.
Installation (Fig. 91)
1. Iffittings wereremoved fromfan motor,lubricate and
place new O--rings onto fittings. Install fittings into port
openingsusingmarksmadeduringtheremovalprocess
to properly orientate fittings. Tighten fittings (see Hy-
draulic Fitting Installation in the General Information
section of this chapter).
2. Position fan motor to fan motor bracket and secure
with cap screws ( item 20), flat washers (item 21) and
lock nuts (item 14).
3. Thoroughly clean tapered surfaces of fan motor
shaft and fan hub. Place woodruff key in slot in motor
shaft.
4. Position fan hub onto motor shaft and secure with
washer (item8) andhex nut (item9). Torque nut from27
to 33 ft--lb (37 to 44 N--m).
IMPORTANT: Make sure to not damage the radiator
or other machine components while installing the
fan motor and bracket assembly.
5. Carefullyposition fan motorandbracket assemblyto
radiator and secure with six (6) cap screws and flange
nuts.
6. Remove caps and plugs placed in hoses and fittings
during removal to prevent contamination. Connect hy-
draulic hoses to cooling fan motor (see Hydraulic Hose
and Tube Installation in the GeneralInformation section
of this chapter).
7. Position fan to fan hub and secure with four (4) cap
screws and washers.
8. Install upper radiator shroud and air cleaner hose
(Fig.92).Make surethat clearancebetween shroudand
cooling fan is at least 0.180” (4.6 mm) at all points.
9. Lower and secure hood.
1. Radiator
2. Upper radiator shroud
3. Screw (4 used)
4. Flange nut (4 used)
5. Air cleaner hose
6. Screw
7. Flat washer
Figure 92
3
5
6
7
1
2
4
Hydraulic
System