Generac Power Systems 17 kW LP Portable Generator User Manual


 
DIVIDER PANEL
DIVIDER PANEL
TO ENGINE
TO ENGINE
6
7
9
8
3
5
4
1
2
10
1. CONTROL PANEL
2. 7.5 AMP FUSE
3. STARTER CONTACTOR RELAY
(10-20 KW)
4. 4 POSITION TERMINAL BLOCK
5. TERMINAL BLOCK
6. CIRCUIT BREAKER (8KW)
7. 15 AMP GFCI DUPLEX OUTLET
(17 & 20 KW)
8. CIRCUIT BREAKER (17 & 20 KW)
9. CIRCUIT BREAKER (10-20 KW)
10. LED DISPLAY
Figure 3. Control Panel Component Identification
DC CONTROL
SECTION 4.1
DESCRIPTION AND COMPONENTS
PART 4
Page 97
7.5 AMP FUSE
This fuse protects the circuit board against excessive
current. If the fuse has blown, engine cranking and
operation will not be possible. Should fuse replace-
ment become necessary, use only an identical 7.5
amp replacement fuse.
Figure 2. A Typical 7.5 Amp Fuse