Generac Power Systems 17 kW LP Portable Generator User Manual


 
12. Remove Brush Wires: Using a side cutters remove the
tie wraps securing the brush wires to the outside of sta-
tor. See Figure 35.
Figure 35.
13. Remove Controls Cover: Using a Torx T-27 socket
remove two bolts and ground washer from the controls
cover. Remove the controls cover. See Figure 36.
Figure 36.
14. Remove Stator Wires: Remove all wires from the voltage
regulator, remove the common and ground wires from
landing lugs, and remove N1 & N2 wires from main bea-
kers. See Figure 37.
Figure 37.
15. Alternator Air Intake Bellows Removal: Remove alterna-
tor intake bellows. See Figure 38.
Figure 38.
16. Rear Bearing Carrier Removal: Using a 13mm socket,
remove the two nuts from the alternator mounting brack-
et rubber mounts. Lift the back end of the alternator up
and place a 2”x 4” piece of wood under the engine. See
Figure 40. Using a 13mm socket, remove the four stator
hold down bolts. See Figure 41. Using a small rubber
mallet remove the rear bearing carrier. See Figure 42.
Remove stator. See Figure 43.
Page 160
PART 6
DISASSEMBLY
SECTION 6.1
MAJOR DISASSEMBLY