Generac Power Systems 17 kW LP Portable Generator User Manual


 
STATOR/ROTOR/ENGINE REMOVAL:
1. Remove Top Exhaust Enclosure Covers: Using a 10mm
socket, remove the nine bolts from the exhaust top cov-
ers. Remove covers. See Figure 23.
Figure 23.
2. Remove Side Exhaust Enclosure Cover: Using a 10mm
socket, remove the five bolts from the exhaust side
cover. Remove side covers. See Figure 24.
Figure 24.
3. Remove Exhaust Flex Cover: Using a 10mm socket,
remove the two bolts from the exhaust flex pipe cover.
Remove the cover. See Figure 25.
Figure 25.
4. Remove Exhaust Flex Pipe: Using a ½” socket remove
the front and rear muffler clamp. Slide exhaust flex
toward engine completely exposing the muffler flange.
See Figure 26.
Figure 26.
5. Remove Muffler and Tail Pipe: Using a ½” socket remove
the muffler clamp and tail pipe. Using a 10mm socket,
remove the four bolts from the muffler mounts and
remove muffler. See Figure 27.
Page 157
DISASSEMBLY
SECTION 6.1
MAJOR DISASSEMBLY
PART 6