Generac Power Systems 17 kW LP Portable Generator User Manual


 
Figure 31.
9. Remove Fan: Attach a steering wheel puller to the fan
using two M8 x 1.25 bolts. Remove the fan from the
rotor. Figure 32.
Figure 32.
10. Remove Brushes: Using a 7mm socket remove brushes.
See Figure 33.
Figure 33.
11. Remove Alternator Divider Panel: Using a 10mm socket
remove two bottom base bolts. Using a T27 torx driver
remove one top rear bolt. Remove the panel. See Figure 34.
Figure 34.
Page 159
DISASSEMBLY
SECTION 6.1
MAJOR DISASSEMBLY
PART 6