Generac Power Systems 17 kW LP Portable Generator User Manual


 
DISASSEMBLY
SECTION 6.1
MAJOR DISASSEMBLY
PART 6
Page 153
4. Remove Stator Wires: Remove all wires from the voltage
regulator, remove the neutral and ground wires from
landing lugs, and remove N1 & N2 wires from main bea-
kers. See Figure 5.
5. Remove Control Wires: Remove Wires #N1,#N2, #0,
#15B, #23, GFCI Outlet, and unit status lights from the
control box. See Figure 6.
Figure 5.
Figure 6.
6. Remove controller mounting box: Using an 8mm socket
remove the two screws from the rear of the control-
ler mounting box. See Figure 7. Using a 10mm socket
remove the two bolts from under the front of the control-
ler mounting box. See Figure 8.
Figure 7.
Figure 8.
7. Remove engine intake baffle: Using a 10mm socket
remove the two bolts from the engine intake baffle. Pull
baffle toward you carefully, there are tabs holding the
backside of the baffle to the divider panel. See Figure 9.
Figure 9.