Groundsmaster 4100--D/4110--D Hydraulic SystemPage 4 -- 3
General Information
Operator’s Manual
The Operator’s Manual provides information regarding
the operation, general maintenance and maintenance
intervals for your Groundsmaster machine. Refer to that
publication for additional information when servicing the
machine.
Check Hydraulic Fluid
Your Groundsmaster hydraulic system is designed to
operate on anti--wear hydraulic fluid. The reservoir
holds approximately 7.75 U.S. gallons (29.3 liters) of
hydraulic fluid. Check level of hydraulic fluid daily.
See Operator’s Manual for fluid level checking proce-
dure and oil recommendations.
1. Hydraulic reservoir 2. Reservoir cap
Figure 1
1
2
Relieving Hydraulic System Pressure
Before disconnecting or performing any work on the hy-
draulic system, all pressure in the hydraulic system
must be relieved. Parkmachine on a levelsurface, make
sure that PTO switch is OFF, lower cutting deck fully,
stop engine and engage parking brake. Wait for all mov-
ing parts to come to a complete stop.
System pressure inlift circuit is relieved when thecutting
deck is fully lowered.
System pressure in mow circuit is relieved when the
PTO switch is disengaged.
To relieve hydraulic pressure in traction circuit, turn igni-
tion switch to ON (engine not running) andmove traction
pedal to both forward and reverse directions. Turn igni-
tion switch to OFF after relieving traction circuit pres-
sure.
To relieve hydraulic pressure in steering circuit, rotate
steering wheel in both directions.
After all hydraulic system pressureshave been relieved,
remove key from ignition switch.
Hydraulic
System