Agilent Technologies 1680 Weather Radio User Manual


 
52
Chapter 3: Testing Performance
To test the multiple-clock state acquisition
b On the oscilloscope, select [Shift] + width: channel 1, then select
[Enter] to display the data signal pulse width (+ width (1)).
c If the pulse width is outside the limits, adjust the pulse generator
channel 2 width until the pulse width is within limits.
Check the setup/hold with single clock edges, multiple
clocks
The following setup/hold combinations will be tested.
Setup/Hold Combinations
1 Disable the pulse generator channel 1 COMP (LED off).
2 Using the Delay mode of the pulse generator channel 1, position the pulses
according to the setup time of the setup/hold combination selected,
+0.0 ps or 100 ps as measured on the oscilloscope:
a On the Oscilloscope, select [Define meas] Define Time - Stop edge:
rising, Edge number 2.
Te s t
Combination
Setup/Hold
Times
Setup/Hold
Window
Sample Position
(in middle of Window)
1 5.0/-2.0 ns 3.0 ns -3.5 ns
2 -1.5/4.50 ns 3.0 ns +3.0 ns