Sun Microsystems 3900 Outdoor Storage User Manual


 
78 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
TABLE 7-1 lists the switch events for Sun StorEdge network FC switch-8 and switch-
16 1 Gbit switches.
TABLE 7-1 Storage Automated Diagnostic Environment Event Grid for 1 Gbit Switches
Component
EventType
Severity
Action
Description
Note:
Text within
quotation marks
(“ “) is exactly
as it appears on
the Event Grid.
Action
Required
port
statistics
Log Yellow Y “Change inport statistics on
switch diag156-sw1b
(ip=192.168.0.31)”
The switch has reported a
change in an error counter.
This could indicate a failing
component in the link.
1. Check the Topology GUI
for any link errors.
2. Quiesce I/O on the link
3. Run linktest on the link
to isolate the failing
FRU.
chassis.
fan
Alarm Yellow Y “chassis.fan.1 status
changed from OK”
None.
system_
reboot
Alarm Yellow Y The uptime of the switch
was less than the previous
uptime of the switch. This
could indicate that the
switch has been reset either
by a user or by the loss of
power.
1. Check to seeif the switch
has been reset.
2. Check the power going
to the switch.
chassis.
power
Alarm Yellow “chassis.power.1 status
changed from OK”
This event monitors
changes in the status of the
chassis’ power supply, as
reported by the SANbox
chassis status.
None.
chassis.
temp
Alarm Yellow “chassis.temp.1 status
changed from OK”
This event monitors
changes in the status of the
chassis’ temperature supply,
as reported by SANbox
chassis status.
None.