158 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
71001 This is a generic error code for the SLIC.It
signifies communication problems between the
virtualization engine and the daemon.
Error halt mode also forces this service request
number.
1. Check the condition of the
virtualization engine.
2. Check the cabling between the
virtualization engine and daemon
server.
71002 The SLIC was busy.
Error halt mode also forces this service request
number.
Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and the daemon
server.
71003 The SLIC master was unreachable. Check conditions of the virtualization
engines in the SAN.
71010 The status of the SLIC daemon has changed. No action is needed.
72000 The primary and secondary SLIC daemon
connection is active.
No action is needed.
72001 The virtualization engine failed to read the SAN
drive configuration.
No action is needed.
72002 The virtualization engine failed to lock on to the
SLIC daemon.
No action is needed.
72003 The virtualization engine failed to read the SAN
SignOn information.
No action is needed.
72004 The virtualization engine failed to read the zone
configuration.
No action is needed.
72005 The virtualization engine failed to check for
SAN changes.
No action is needed.
72006 The virtualization engine failed to read the SAN
event log.
No action is needed.
72007 The SLIC daemon connection is down. Wait 1 to 5 minutes for the backup
daemon to come up. If it doesn’t, check
the network connection for virtualization
engine halt, or hardware failure.
TABLE A-1 SRN Reference
SRN Description Corrective Action