Sun Microsystems 3900 Outdoor Storage User Manual


 
96 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
TABLE 8-1 lists all of the events for the Sun StorEdge T3+ array.
TABLE 8-1 Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event Type
Severity
Action
Description
Action
power.temp Alarm+ The power temperature
is normal.
sysvolslice Alarm Yellow Y The vol slice feature is
possible in Sun StorEdge
T3+ array firmware
version 2.1 and above.
This option enables
volume slicing, up to 16
LUN per single Sun
StorEdge T3+ array or
partner group. This
feature also enables LUN
masking (HBA zoning)
features.
This option is disabled
by default. To activate
the feature, type
sys_enable_volslice_on
from the Sun StorEdge
T3+ array command line.
disk.port Alarm- Red Y The Sun StorEdge T3+
array has reported that
one port of a dual-ported
disk has failed.
1. Open a Telnet session
to the affected Sun
StorEdge T3+ array.
2. Verify disk state in
fru stat, fru list,
and vol stat.