Chapter 5 Troubleshooting the Fibre Channel (FC) Links 57
Sun Proprietary/Confidential: Internal Use Only
CODE EXAMPLE 5-6 DMP Error Message
Verifying the Storage Service Processor-Side
You can check the A3 or B3 FC link using the Storage Automated Diagnostic
Environment’s Test from Topology functionality.
The Storage Automated Diagnostic Environment’s implementation of diagnostic
tests verifies the operation of user-selected components. Using the Topology view,
you can select specific tests, subtests, and test options.
Refer to the Storage Automated Diagnostic Environment User’s Guide for more
information.
FRU Tests Available for the A3 or B3 FC Link
Segment
■ The linktest is not available.
■ Both the switch and the GBIC are tested using the switchtest test. The
switchtest test:
■ Can be used only in conjunction with the loopback connector
■ Cannot be cabled to the virtualization engine while switchtest runs
■ No virtualization engine tests are available at this time.
Jul 8 18:26:38 diag.xxxxx.xxx.com vxdmp: [ID 619769 kern.notice] NOTICE:
dmp: Path failure on 118/0x1f8
Jul 8 18:26:38 diag.xxxxx.xxx.com vxdmp: [ID 997040 kern.notice] NOTICE:
vxvm:vxdmp: disabled path 118/0x1f8 belonging to the dmpnode 231/0xd0