Sun Microsystems 3900 Outdoor Storage User Manual


 
46 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
An error in the A1 or B1 FC link can also cause a device to enter the “unusable” state
in cfgadm -al, as shown in
CODE EXAMPLE 5-2.
CODE EXAMPLE 5-2 cfgadm -al Display
FRU Tests Available for the A1 or B1 FC Link
Segment
The following FRU tests are available for the A1 or B1 FC link segment. All
diagnostics are located in /opt/SUNWstade/Diags/bin. Refer to the man pages
for more details.
HBA—qlctest(1M)
Available only if the Storage Automated Diagnostic Environment is installed
on a data host
Causes HBA to go offline and online during tests
Switch —switchtest(1M)
Can be run while the link is still cabled and online (connected to HBA)
Can be run only from the Storage Service Processor.
The dev option to switchtest is in the following format:
Port:IP-Address:FCAddress
The FCAddress can be set to 0x0.
Note – If you are testing an A1 or B1 FC link that is connected to an HBA, you must
specify a payload of 200 bytes or less. This is a limitation in the HBA application-
specific integrated circuit (ASIC).
# /usr/sbin/cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t6d0 CD-ROM connected configured unknown
c2 fc-fabric connected configured unknown
c2::210100e08b23fa25 unknown connected unconfigured unknown
c2::2b000060220041f4 disk connected configured unknown
c3 fc-fabric connected configured unknown
c3::2b000060220041f9 disk connected configured unusable
c4 fc-private connected unconfigured unknown
c5 fc connected unconfigured unknown