Sun Microsystems 3900 Outdoor Storage User Manual


 
70 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
Component
EventT ype
Severity
Action
Description
Information
ifptest Diagnostic
Test-
Red Y ifptest (diag240) on the
host failed.
Check Test Manager for
failure details.
qlctest Diagnostic
Test-
Red qlctest (diag240) on the
host failed.
Check Test Manager for
failure details.
socal
test
Diagnostic
Test-
Red socaltest (diag240) on
the host failed.
Check Test Manager for
failure details.
enclosure PatchInfo New patch and package
information were
generated.
Send changes to the output
of
showrev -p and
pkginfo -|.
enclosure backup The Agent was backed up. Backs up the configuration
file of the Agent.
disk_
capacity
Alarm Yellow Y Detected that
/var/opt/SUNWstade is
at or above 98% capacity
by typing:
/usr/sbin/df -k /
var/opt/SUNWstade
Remove unused files and
directories to free up space.
Use a larger disk for
/var/opt/SUNWstade
disk_
capacity_
okay
Alarm Detected that
/var/opt/SUNWstade is
now below 98% capacity
by typing:
/usr/sbin/df -k /
var/opt/SUNWstade
No action is required.
TABLE 6-1 Storage Automated Diagnostic Environment Event Grid for the Host (Continued)