Sun Microsystems 3900 Outdoor Storage User Manual


 
Chapter 10 Troubleshooting Using Microsoft Windows 2000 143
Sun Proprietary/Confidential: Internal Use Only
FIGURE 10-7 displays example ouput for a Sun StorEdge 3900 series system from the
jafo_nutil.exe interface.
FIGURE 10-7 Sun StorEdge T3+ Array Failover Driver CLI Output for the Sun StorEdge
3900 Series
# E:\Program Files\Sun Microsystems\T3 Storedge Multiplatform Driver>
jafo_nutil.exe
HBA WWN:00000000000000000000000000000000 NAME:Device\ScsiPort5
DESC:QLogic QLA2200 PCI Fibre Channel Adapter DRIVER:ql2200
FW_REV:Can’t obtain from OS
HBA WWN:00000000000000000000000000000000 NAME:Device\ScsiPort4
DESC:QLogic QLA2200 PCI Fibre Channel Adapter DRIVER:ql2200
FW_REV:Can’t obtain from OS
DEVICE VENDOR:Sun Microsystems T3 Disk Array FW_REV:0201
SERIAL:00163874 WWN:60020f20000003d50000000000000000
FO_CAPABLE:true MASTER:true
LUN NAME:G: WWN:60020f20000003d53cf7c0f500028022 GOOD_PATHS:2
STATE:up(1)
PATH NAME:5,0,0,0 HBA_NAME:Device\ScsiPort5 TARGET:0,0,0
TYPE:secondary STATE:up_standby(3)
PATH NAME:4,0,0,0 HBA_NAME:Device\ScsiPort4 TARGET:0,0,0
TYPE:primary STATE:up_active(2)
CONTROLLER ID:0 DESC:Sun T3 Disk Array Controller
DEVICE VENDOR:Sun Microsystems T3 Disk Array FW_REV:0201
SERIAL:00524894 WWN:60020f20000003d50000000000000000
FO_CAPABLE:true MASTER:false
LUN NAME:H: WWN:60020f20000003d53cf7c4640008025e GOOD_PATHS:2
STATE:up(1)
PATH NAME:5,0,0,5 HBA_NAME:Device\ScsiPort5 TARGET:0,0,0
TYPE:primary STATE:up_active(2)
PATH NAME:4,0,0,5 HBA_NAME:Device\ScsiPort4 TARGET:0,0,0
TYPE:secondary STATE:up_standby(3)
CONTROLLER ID:0 DESC:Sun T3 Disk Array Controller