Sun Microsystems 3900 Outdoor Storage User Manual


 
Chapter 5 Troubleshooting the Fibre Channel (FC) Links 63
Sun Proprietary/Confidential: Internal Use Only
To verify that the failover luxadm display can be used, the failed path is marked
“offline,” as shown in
CODE EXAMPLE 5-7.
CODE EXAMPLE 5-7 Failed Path Marked Offline
Note This type of error may also cause the device to show up as "unusable" in
cfgadm, as shown in CODE EXAMPLE 5-8.
# /usr/sbin/luxadm display /dev/rdsk/c26t60020F200000644>
DEVICE PROPERTIES for disk: /dev/rdsk/
c26t60020F20000064433C3352A60003E82Fd0s2
Status(Port A): O.K.
Status(Port B): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f2000006443
WWN(Port A): 50020f2300006355
WWN(Port B): 50020f2300006443
Revision: 0118
Serial Num: Unsupported
Unformatted capacity: 488642.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2
/devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw
Controller /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0
Device Address 50020f2300006355,1
Class primary
State OFFLINE
Controller /devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0
Device Address 50020f2300006443,1
Class secondary
State ONLINE