Sun Microsystems 3900 Outdoor Storage User Manual


 
170 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
setswitchflash Invalid flash file $flashfile.
Check the number of ports on switch
$switch.
You might be attempting to download
a flash file for an 8-port switch to a 16-
port switch. Check showswitch -s
$switch and look for “number of
ports.” Ensure that this matches the
second and third characters of the
flash file name.
setswitchflash ${switch} timed out after reset.
The switch took longer than two
minutes to reset after a configuration
change.
The switch might not be set for rarp,
or rarp is not working correctly.
1. Wait several minutes.
2. Run ping $switch.
3. If errors persist, manually power
cycle the switch.
setupswitch Switch ${switch} timed out after
reset.
The switch took longer than two
minutes to reset after a configuration
change.
1. Wait several minutes.
2. Run ping $switch
3. If errors persist, manually power
cycle the switch.
setupswitch Could not set chassis ID on switch
${switch} to ${cid}.
This occurs only in a SAN
environment with cascaded switches.
1. Check the switch chassis IDs of all
switches in the SAN.
2. Verify that each ID is unique.
3. After the chassis IDs have been
established, override the switch
chassis IDs with the following
command:
setupswitch -s
$switch_name -i
$unique_chassis_id -v.