130 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
2. Run the showswitch(1M) command for sw2a and sw2b.
Refer to the Sun StorEdge 3900 and 6900 Series 2.0 Reference and Service Manual to see
to which switch ports the Sun StorEdge T3+ array and virtualization engine should
be attached.
In this example, the Sun StorEdge T3+ array (t3b0) should be attached to port 2 of
sw2a and sw2b and the virtualization engine should be attached to port 1. All ports
should be online.
# showswitch -s sw2a
************
Port Status
************
Port # Port Type Admin State Oper State Status Loop
Mode
------ --------- ----------- ---------- ------ -----
1 F_Port online online logged-in
2 TL_Port online offline Not-logged-in
3 TL_Port online offline Not-logged-in
4 TL_Port online offline Not-logged-in
5 TL_Port online offline Not-logged-in
6 TL_Port online offline Not-logged-in
7 T_Port online online logged-in
8 T_Port online online logged-in
************
Name Server
************
Port Address Type PortWWN Node WWN FC-4 Types
---- ------- ---- ---------------- ---------------- -----------------
01 10C000 N 2900006022004195 2800006022004195 SCSI_FCP
...
Here, port 2 on sw2a is offline. If required ports are offline, then check
the GBICs and cables. If a Sun StorEdge T3+ array switch port is offline,
then login to the T3+ array and look at the status of the controllers and
the port list as follows:
t3b0:/:<1>fru stat u1c1
CTLR STATUS STATE ROLE PARTNER TEMP
------ ------- ---------- ---------- ------- ----
u1ctr ready disabled - - -
t3b0:/:<2>fru stat u2c1
CTLR STATUS STATE ROLE PARTNER TEMP
------ ------- ---------- ---------- ------- ----
u2ctr ready enabled master - 27.0
t3b0:/:<3>port list
port targetid addr_type status host wwn
u1p1 0 hard offline sun 50020f2300006dfa
u2p1 1 hard online sun 50020f230000725b