Sun Microsystems 3900 Outdoor Storage User Manual


 
Appendix A Virtualization Engine References 161
Sun Proprietary/Confidential: Internal Use Only
050 An attempt to write a value into
nonvolatile storage failed,
perhaps because a hardware
failure, or one of the databases
stored in Flash memory could
not accept the entry being
added.
Clear the SAN database.
Cycle power to the
virtualization engine.
051 The virtualization engine cannot
erase Flash memory.
Replace the virtualization
engine.
53 The cabling configuration is
unauthorized.
Check the cabling. Ensure the
server and switch connect to the
host side and the storage
connects to the device side of the
virtualization engine.
If necessary, clear the SAN
database.
If necessary, cycle the
virtualization engine power.
If necessary, import the SAN
zone configuration.
54 The cabling configuration is
unauthorized.
Check the cabling.
57 Too many HBAs are attempting
to log in.
Check the cabling.
60 The node mapping table was
cleared using SW2.
No action required.
62 SW2 settings are incorrect.. Correct the SW2 setting.
Cyclethe virtualizationengine
power.
126 Too many virtualization engines
in the SAN.
Remove the extra
virtualization engine.
Cyclethe virtualizationengine
power.
130 The connection between
virtualization engines is down.
Correct the problem.
Cycle the power on the
follower virtualization engine.
TABLE A-4 Virtualization Engine Service Codes (Continued)—0 -399 Host-Side Interface Driver Errors