Appendix A Virtualization Engine References 161
Sun Proprietary/Confidential: Internal Use Only
050 An attempt to write a value into
nonvolatile storage failed,
perhaps because a hardware
failure, or one of the databases
stored in Flash memory could
not accept the entry being
added.
• Clear the SAN database.
• Cycle power to the
virtualization engine.
051 The virtualization engine cannot
erase Flash memory.
• Replace the virtualization
engine.
53 The cabling configuration is
unauthorized.
• Check the cabling. Ensure the
server and switch connect to the
host side and the storage
connects to the device side of the
virtualization engine.
• If necessary, clear the SAN
database.
• If necessary, cycle the
virtualization engine power.
• If necessary, import the SAN
zone configuration.
54 The cabling configuration is
unauthorized.
• Check the cabling.
57 Too many HBAs are attempting
to log in.
• Check the cabling.
60 The node mapping table was
cleared using SW2.
• No action required.
62 SW2 settings are incorrect.. • Correct the SW2 setting.
• Cyclethe virtualizationengine
power.
126 Too many virtualization engines
in the SAN.
• Remove the extra
virtualization engine.
• Cyclethe virtualizationengine
power.
130 The connection between
virtualization engines is down.
• Correct the problem.
• Cycle the power on the
follower virtualization engine.
TABLE A-4 Virtualization Engine Service Codes (Continued)—0 -399 Host-Side Interface Driver Errors