150 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
FIGURE 11-4 Diagnostics Using QLogic SunBlade
In this example, the HBA-to-switch cable was removed temporarily and a loopback
connector was inserted into the HBA. The Qlogc SANblade LoopBack diagnostics
were then run. The HBA passed the tests.
Note The next components that can be isolated are the switch-side GBIC and the
Sun StorEdge network FC switch itself.
For these components, you can launch the tests using the Storage Automated
Diagnostic Environment Diagnose -> Tests -> Test From Topology functionality.
5. Again, temporarily remove the cable from the switch port in question, insert a
loopback connector plug and run the switch port diagnostics.
The first run will test the switch-side GBIC as well as the Sun StorEdge network FC
switch.