Sun Microsystems 3900 Outdoor Storage User Manual


 
Chapter 8 Troubleshooting the Sun StorEdge T3+ Array Devices 99
Sun Proprietary/Confidential: Internal Use Only
enclosure Audit Auditing a new Sun
StorEdge T3+ array
Audits occur everyweek.
The Storage Automated
Diagnostic Environment
sends a detailed
description of the
enclosure to the Sun
Network Storage
Command Center
(NSCC).
ib Comm_
Established
Communicationregained
InBand (ib)
oob Comm_
Established
Communicationregained
oob (OutOfBand)
ib Comm_Lost Down Y Since InBand (ib)
monitoring is established
using luxadm, the
monitoring may not be
activated for a particular
Sun StorEdge T3+ array.
1. Verify luxadm with
the command line
(luxadm probe,
luxadm display)
2. Verify cables, GBICs,
and connectionsalong
the data path.
3. Check the Storage
AutomatedDiagnostic
Environment SAN
Topology GUI to
identify the failing
segment of the data
path.
4. Verify the correct FC
switch configuration,
if applicable.
TABLE 8-1 Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event Type
Severity
Action
Description
Action