156 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
TABLE A-1 SRN Reference
SRN Description Corrective Action
1xxxx The SCSI Request Sense command has
reported the condition of the disk drive, where
xxxx is the Unit Error Code in Sense Data bytes
20 to 21.
If too many check conditionsare returned,
check the link status.
70000 The SAN configuration has changed. No action is needed.
70001 The rebuild process has started. No action is needed.
70002 The rebuild completed without error. No action is needed.
70003 The drive copying information cannot be read
from the primary drive.
If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.
70004 If the initiator is master, then its follower has
detected a write error on a member within a
mirror drive.
If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.
70005 If the initiator is master, then it has detected a
write error on a member within a mirror drive.
If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.
70006 Communication between the virtualization
engines has failed.
Update the firmware.
70007 The primary drive cannot write to the drive
being built.
If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.
70008 If the initiator is master, then its slave has
detected a read error on a member within a
mirror drive.
If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.
70009 If the initiator is master, then it has detected a
read error on a member within a mirror drive.
If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.
70010 The CleanUp configuration table is completed. No action is needed.
70020 The SAN physical configuration has changed. If the change was unintentional, check the
condition of the drives.