Troubleshooting Using Microsoft
Windows 2000
General Notes
Use the Manufacturer’s HBA Utilities to monitor and diagnose the HBAs. The
examples in this chapter use Qlogic’s SANblade Manager utility.
The Storage Automated Diagnostic Environment running on the Storage Service
Processor is not able to monitor the host-to-switch link.
The Storage Automated Diagnostic Environment running the Storage Service
Processor is not able to execute switchtest(1M) on switch ports with Microsoft
Windows 2000 HBAs currently attached as F ports.
The FRUs in the host-to-switch link can be isolated using the HBA utilities on the
host and Storage Automated Diagnostic Environment’s switchtest on the
Storage Service Processor, in conjunction with loopback connector plugs.
Install the Sun StorEdge T3+ array Failover Driver software before connecting the