SRN/SNMP Single Point-of-Failure
Descriptions
TABLE A-2 provides Simple Network Management Protocol (SNMP) descriptions,
associated Service Request Numbers (SRNs), and recommendations for corrective
action.
TABLE A-2 SRN/SNMP Single Point-of-Failure Table
SRN SNMP Description Corrective Action
SRN after
Corrective
Action
70020
70021
70030
70050*
The SAN topology has changed.
The Global SAN configuration has
changed.
The SAN configuration has
changed.
A physical device is missing.
Check the SAN cabling and
connections between the Sun
StorEdge T3+ array andthe
virtualization engine.
Perform Sun StorEdge T3+ array
failback, if necessary.
70020
70030
70051**
70025 The IP of the partner’s virtualization
engine is not reachable.
Check the Ethernet cabling and
connections.
None
72000
72007
70020
70021
70022
70025
70030
70050
The SAN topology has changed.
The Global SAN configuration has
changed.
The SAN configuration has
changed.
The IP of the partner virtualization
engine is not reachable.
A physical device is missing.
•ASLIC virtualization engine is
missing.
•ASLIC daemon connection is
inactive.
The virtualization engine failed to
check for SAN changes, or a daemon
error occurred.
A secondary daemon connection is
active.
Check cabling and connections
between the virtualization engines.
Cycle power on failed
virtualization engine, if the fault LED
flashes.
Perform Sun StorEdge T3+ array
failback, if necessary.
Enable VERITAS path.
Check the SLIC virtualization
engine.
70020
70021
70022
70024*
70030
70050
* Sun StorEdge T3+ array LUN failover.