Sun Microsystems 3900 Outdoor Storage User Manual


 
Chapter 9 Troubleshooting Virtualization Engine Devices 127
Sun Proprietary/Confidential: Internal Use Only
4. To restart the slicd for the v1 virtualization engine, type:
5. Confirm that the slicd daemon is running:
If the slicd daemon is running, it resets the virtualization engine. If the process
fails, the slicd daemon changes the IP address to that of the second virtualization
engine and attempts to restart the slicd process.
6. If the second virtualization engine fails, power cycle the virtualization engines
and make sure they are not in an ERROR HALT 50 condition.
An ERROR HALT 50 condition requires that you visually inspect the virtualization
engines with firmware revision 8.14 or earlier.
For virtualization engines with firmware revision 8.17 or later, you can determine
error conditions with the following steps:
a. Open a Telnet session into v1_hostname.
b. Display the Vital Product Data (VPD) by entering .1 at the prompt.
The last line of the output displays any error codes, as shown in the following
example.
# /opt/SUNWsecfg/bin/startslicd -n v1
(or v2, depending on configuration)
# ps -ef | grep slicd
root 16132 16130 0 11:45:00 ? 0:00 ./slicd
root 16135 16130 0 11:45:00 ? 0:00 ./slicd
root 16130 1 0 11:45:00 ? 0:00 ./slicd
root 16131 16130 0 11:45:00 ? 0:00 ./slicd
root 16189 15877 0 11:48:49 pts/1 0:00 grep slicd
root 16143 16130 0 11:45:00 ? 0:00 ./slicd