Appendix B Configuration Utility Error Messages 173
Sun Proprietary/Confidential: Internal Use Only
checkt3mount • The $lun status reported a bad or
nonexistent LUN.
• While checking the configuration
using the showt3 -n command,
operations abort.
1. Run the showt3 -n command to
verify that the requested LUN
exists on the Sun StorEdge T3+
array.
2. Confirm that the Sun StorEdge
T3+ array configuration matches
standard configurations.
createt3group User-specified LUN $lun does not
exist on the Sun StorEdge T3+ array.
Create the required slice or LUN
before you set permissions using the
createt3slice command.
createt3group Unable to set permissions on the
LUN $lun to $perm for new group.
Refer to the Sun StorEdge T3 andT3+
array documentation.
createt3group Error while resetting permissions on
LUN $lun to NONE for group
$group.
Refer to the Sun StorEdge T3 andT3+
array documentation.
delfromt3group Error deleting the world wide name
(WWN) $wwn from group.
Refer to the Sun StorEdge T3 andT3+
array documentation.
enablevolslicing Error checking the Sun StorEdge T3+
enable volume slicing status.
1. Check the Sun StorEdge T3+ array
firmware level and verify it is
2.01.00 or higher.
2. Check if volume slicing is
supported and enabled on the Sun
StorEdge T3+ array.
enablevolslicing Cannot enable volume slicing. The
Sun StorEdge T3+ array firmware
does not support this feature.
1. Check the Sun StorEdge T3+ array
firmware level and verify it is
2.01.00 or higher.
2. Upgrade the firmware, if required.
modifyt3config • The lock file clear waiting period
expired.
• The creatediskpools command
aborted.
1. Check to see if any secfg T3+
commands are being executed.
2. If the commands are executing,
wait for them to complete.
3. Run creatediskpools -n
t3name.
restoret3config • An error occurred while the block
size compare command was
executing.
• The Sun StorEdge T3+ array block
size parameter is different from the
snapshot file. The Sun StorEdge T3+
array may have been reconfigured.
Run the restoret3config
command.
TABLE B-3 Sun StorEdge T3+ Array Error Messages (Continued)
Source of Error Message Cause of Error Message Suggested Corrective Action