Sun Microsystems 3900 Outdoor Storage User Manual


 
Appendix B Configuration Utility Error Messages 173
Sun Proprietary/Confidential: Internal Use Only
checkt3mount The $lun status reported a bad or
nonexistent LUN.
While checking the configuration
using the showt3 -n command,
operations abort.
1. Run the showt3 -n command to
verify that the requested LUN
exists on the Sun StorEdge T3+
array.
2. Confirm that the Sun StorEdge
T3+ array configuration matches
standard configurations.
createt3group User-specified LUN $lun does not
exist on the Sun StorEdge T3+ array.
Create the required slice or LUN
before you set permissions using the
createt3slice command.
createt3group Unable to set permissions on the
LUN $lun to $perm for new group.
Refer to the Sun StorEdge T3 andT3+
array documentation.
createt3group Error while resetting permissions on
LUN $lun to NONE for group
$group.
Refer to the Sun StorEdge T3 andT3+
array documentation.
delfromt3group Error deleting the world wide name
(WWN) $wwn from group.
Refer to the Sun StorEdge T3 andT3+
array documentation.
enablevolslicing Error checking the Sun StorEdge T3+
enable volume slicing status.
1. Check the Sun StorEdge T3+ array
firmware level and verify it is
2.01.00 or higher.
2. Check if volume slicing is
supported and enabled on the Sun
StorEdge T3+ array.
enablevolslicing Cannot enable volume slicing. The
Sun StorEdge T3+ array firmware
does not support this feature.
1. Check the Sun StorEdge T3+ array
firmware level and verify it is
2.01.00 or higher.
2. Upgrade the firmware, if required.
modifyt3config The lock file clear waiting period
expired.
The creatediskpools command
aborted.
1. Check to see if any secfg T3+
commands are being executed.
2. If the commands are executing,
wait for them to complete.
3. Run creatediskpools -n
t3name.
restoret3config An error occurred while the block
size compare command was
executing.
The Sun StorEdge T3+ array block
size parameter is different from the
snapshot file. The Sun StorEdge T3+
array may have been reconfigured.
Run the restoret3config
command.
TABLE B-3 Sun StorEdge T3+ Array Error Messages (Continued)
Source of Error Message Cause of Error Message Suggested Corrective Action