Sun Microsystems 3900 Outdoor Storage User Manual


 
4 Sun StorEdge 3900 and 6900 2.0 Series Troubleshooting Guide March 2003
Sun Proprietary/Confidential: Internal Use Only
1. Discover the error by checking one or more of the following messages or files:
Storage Automated Diagnostic Environment alerts or email messages
/var/adm/messages
Sun StorEdge T3+ array syslog file
Storage Service Processor messages
/var/adm/messages.t3 messages
/var/adm/log/SEcfglog file
2. Determine the extent of the problem by using one or more of the following
methods:
Review the Storage Automated Diagnostic Environment topology view.
Using the Storage Automated Diagnostic Environment revision checking
functionality, determine whether the package or patch is installed.
Verify the functionality using one of the following tools:
checkdefaultconfig(1M)
cfgadm -al output
luxadm(1M) output
Review the multipathing status using the Sun StorEdge Traffic Manager (MPxIO)
software or vxdmp(1M) command.
3. Check the status of a Sun StorEdge T3+ array by using one or more of the
following methods:
Review the Storage Automated Diagnostic Environment device monitoring
reports.
Run the checkt3config(1M) and showt3(1M) commands, which check and
display the Sun StorEdge T3+ array configuration.
Manually open a Telnet session to the Sun StorEdge T3+ array.
Review the luxadm(1M) display output.
Review the LED status on the Sun StorEdge T3+ array.
Review the Explorer Data Collection Utility output, which is located on the
Storage Service Processor.