Sun Microsystems 3900 Outdoor Storage User Manual


 
Chapter 7 Troubleshooting Switches 85
Sun Proprietary/Confidential: Internal Use Only
setupswitch Exit Values
TABLE 0-1 lists the setupswitch exit values. The associated messages are logged in
the /var/adm/log/SEcfglog file.
TABLE 0-1 setupswitch Exit Values
Severity
Level Message Type Message Meaning
0 INFO All switch settings are properly set. The switch setting matches the default
configuration.
1 ERROR Errors occurred while you tried to set the proper switch settings.The
switch setting does not match the default configuration or any valid
alternatives.
2 WARNING Errors occurred while you tried to set the proper switch settings. The ports
did not self-configure properly. A cable connection might not be working
properly. T ports self-configure (that is, the configuration tool cannot
control the configuration) from F ports when they are cabled properly.
Specifically, these are the ports on the back-end switches in Sun StorEdge
6900 series configurations only. The ports support the ISL connections.
3 WARNING The Flash code is different from the release level. The switch Flash code
does not match the current release version. The Sun StorEdge network FC
switch-8 and switch-16 switches periodically releases new versions of the
switch Flash code and the new version will not match the default version.
4 WARNING The configuration is not set to the default, but the differences are likely
supported alternatives. The default switch configurations were overridden
with valid alternatives, which are also supported by the SUNWsecfg
configuration tools. It should still be flagged as “not the default.” The exit
value can imply any of the following alternatives (these messages are
printed to the screen and to the Storage Automated Diagnostic
Environment GUI):
Some ports have been set to SL, TL, or F mode, but should have been set
using the setswitcht1 or setswitchf commands. View and verify this
nonstandard configuration setup as required, using the showswitch
command. Refer to the Sun StorEdge 3900 and 6900 Series Version 1.1
Reference and Service Guide for detailed configuration information.
The chassis ID on the switch is not set to the default value. This could be
caused by unique ID settings or by conflicts in a SAN environment.
Ports are identified that are not in the default hard zone. This could be
because the port is set to the same hard zone as the cascaded switch in a
SAN environment or the user has run the modifyswitch(1M) command
on a Sun StorEdge 3900 Series system