Performance Verification
MTG100 & MTG300 MPEG Generator Service Manual
4Ć11
MPEG generator rear panel
Parallel interface cable
MPEG test system rear panel
(MTS200 or MTS215 Opt. SS)
Figure 4Ć7: Equipment connection for verifying the parallel output
7. Double-click the Real Time Analyzer icon in the MPEG test system’s
Program Group window to start the application.
8. In the Real Time Analyzer window on the MPEG test system, select
Settings... from the Configuration menu to open the Settings window.
9. In the Settings window, select Hardware Configuration to open the
Hardware Configuration window.
10. In the Hardware Configuration window, click the Restore Defaults button,
click the Apply button, and then select DVB-PI SPI (LVDS//) or ECL// as
the Input Type.
11. In the Settings window, select ETR290 to open the ETR290 configuration
window.
12. In the ETR290 window, click the Restore Defaults button, click the Apply
button, and then click OK to close the Settings window.
13. In the Real Time Analyzer window, click the Start Analysis toolbar button.
14. Verify that the Hierarchic view is displayed on the screen and that no error
messages appear. In addition, verify that the transmission rate is 64 Mbps
and that the transport stream packet size is 188 bytes.
15. In the Real Time Analyzer window, click the Stop Analysis toolbar button
to stop analysis.
16. Press the START/STOP button on the MPEG generator to stop the
signal output.