Tektronix MTG100, MTG300 Portable Generator User Manual


 
Removal and Installation Procedures
6Ć36
MTG100 & MTG300 MPEG Generator Service Manual
b. Use a flat–bladed screwdriver to press down on top of the power switch
and push the switch out of the Bracket.
7. Remove the RFI filter: See Figure 6-17.
a. Unplug the two cables from the RFI filter.
b. Using a screwdriver with a size Phillips #2 tip, remove the screw
securing the ground lead to the bracket.
c. Using a screwdriver with a size Phillips #2 tip, remove the two screws
securing the inlet to the bracket. Pull the RFI filter away.
RFI Filter
Power
switch
12V Power supply
Ground lead
Bracket
Blk to L terminal on 5V supply
Blk to top RFI filter connector
Wht to N terminal on 5V supply
Wht to bottom RFI filter connector
Blk
Wht
5V Power supply
Figure 6Ć17: 5 V power supply, 12 V power supply, power switch, and inlet removal
8. Reinstallation:
a. Perform steps 4 through 7 in reverse order to reinstall all the modules.
b. Perform step 3 in reverse order to reinstall the power supply unit.