Mitsubishi Electronics SW0D5C-QD75P-E Weather Radio User Manual


 
10 - 3
MELSEC-Q
10. POSITIONING DEBUGGING
10.2 Monitor
Monitor the positioning data and block start data execution states on an axis by axis
basis, or perform detailed monitor of the error histories, signal states, present values,
speeds, etc. on a project basis.
10.2.1 Monitoring the positioning data/block start data
PURPOSE
From the positioning data/block start data edit window of any axis, monitor the
positioning data No.s or block No.s and point No.s being executed.
BASIC OPERATION
1. Choose the positioning or block start data edit window.
Double-click.
Double-click.
2. Click the [Online]
[Monitor]
[Monitor On/Off] menu (
).
3. To exit, click the [Online]
[Monitor]
[Monitor On/Off] menu ( ).
DISPLAY/SETTING SCREEN
[For positioning data monitor]
DISPLAY/SETTING DATA
Item Description
Positioning data
monitor/block start data
monitor
For positioning data monitor, the positioning data in execution is highlighted.
For block start data monitor, the point in execution is highlighted.