Mitsubishi Electronics SW0D5C-QD75P-E Weather Radio User Manual


 
11 - 4
MELSEC-Q
11. USEFUL FUNCTIONS
11.1.3 Intelligent function utility
PURPOSE
Make setting to read the following data automatically from the QD75 buffer
memory to the QCPU devices (e.g. data registers).
The set data are stored in the intelligent function module parameters of the GPPW
project.
• Feed present value • Machine feed value • Feed speed
• Error No. • Warning No. • Enable M code
• Axis operating status
Automatic refresh allows the above data of the QD75 to be imported to the QCPU
without creation of a sequence program.
BASIC OPERATION
1. Set the required project as the active project. (Refer to Section 5.2.)
2. Click the [Tool]
[Intelligent function utility] menu.
3. Choose the target GPPW project in the GPPW project dialog box.
4. The intelligent function module utility starts.
5. Set Start I/O No., Package name and Module model name.
6. Click the "Auto refresh" button.
7. Assign the CPU side devices to the automatic refresh items in the Auto refresh
setting dialog box.
8. Click the "End setup" button.
9. Click the "Exit" button in the Intelligent function module utility.
10. Click the "Yes" button in the intelligent function module parameter save
confirmation dialog box.
DISPLAY/SETTING SCREEN
[GPPW project dialog box] [Intelligent function module utility]