Mitsubishi Electronics SW0D5C-QD75P-E Weather Radio User Manual


 
8 - 12
MELSEC-Q
8. DATA SETTING
8.4 Block Start Data Setting
Set the block start data for controlling a positioning start and the condition data used as
a condition for a special start.
• The block start data is equivalent to the start block data of the AD75.
8.4.1 Block start data
PURPOSE
Specify the positioning data No. as a point, and set the block start data which sets
the starting condition, execution order and execution count to each point.
You can set up to 50 points per block.
There are blocks No. 0 to 4 per axis.
BASIC OPERATION
1. Choose the block start data.
Double-click. Double-click.
2. Make settings in the block start data edit window.
DISPLAY/SETTING SCREEN
Double-click the cell and make settings in the text box or list box.
When performing operation from the keyboard, enter the value and press the
"Enter" key to determine the value.
For "Pattern" and "Special start", press the "space" key to display a list.
Make selection with the "
" or " " key, and press the "Enter" key to determine the
value.